Rat CD117/c-kit ELISA Kit (Colorimetric) Summary
| Specificity |
This kit recognizes Rat CD117/c-kit in samples. No significant cross-reactivity or interference between Rat CD117/c-kit and analogues was observed. |
| Standard Curve Range |
0.78 - 50 ng/mL |
| Sensitivity |
0.47 ng/mL |
| Assay Type |
Sandwich-ELISA |
| Inter-Assay |
4.98 |
| Intra-Assay |
5.4 |
| Spike Recovery |
86-109 % |
| Sample Volume |
100 ul |
| Kit Type |
ELISA Kit (Colorimetric) |
| Gene |
KIT |
Applications/Dilutions
Packaging, Storage & Formulations
| Storage |
Storage of components varies. See protocol for specific instructions. |
Kit Components
|
Components
|
- Biotinylated Detection Ab Diluent
- Concentrated Biotinylated Detection Ab (100x)
- Concentrated HRP Conjugate (100x)
- Concentrated Wash Buffer (25x)
- HRP Conjugate Diluent
- Micro ELISA Plate (Dismountable)
- Plate Sealer
- Product Manual
- Reference Standard
- Sample Diluent
- Stop Solution
- Substrate Reagent
|
Alternate Names for Rat CD117/c-kit ELISA Kit (Colorimetric)
Background
CD117 is a 145 kD immunoglobulin superfamily member, also known as c-Kit and stem cell factor receptor (SCFR). It is a transmembrane tyrosine-kinase receptor that binds the c-Kit ligand (also known as steel factor, stem cell factor, and mast cell growth factor). CD117 is expressed on hematopoietic stem cells (including multipotent hematopoietic stem cells, progenitors committed to myeloid and/or erythroid lineages, and T and B cell precursors), mast cells, and acute myeloid leukemia (AML) cells. CD117 interaction with it's ligand is critical for the development of hematopoietic stem cells. The 2B8 antibody does not block c-Kit activity.
Limitations
This product is for research use only and is not approved for use in humans or in clinical diagnosis. ELISA Kits are
guaranteed for 6 months from date of receipt.
Customers Who Viewed This Item Also Viewed...
Species: Hu
Applications: BA
Species: Rt
Applications: IHC, WB
Species: Mu
Applications: Flow, IHC, Neut, WB
Species: Hu
Applications: BA
Species: Hu, Mu
Applications: ICC, IHC
Species: Mu
Applications: ELISA
Species: Hu
Applications: CyTOF-ready, Dual ISH-IHC, ELISA(Cap), ELISA(Det), ELISA(Sta), Flow, ICC, IHC, IP, Simple Western, WB
Species: Hu
Applications: CyTOF-ready, Flow
Species: Hu
Applications: BA
Species: Hu
Applications: CyTOF-ready, ELISA, Flow, ICC/IF, IHC, IHC-P, PA, WB
Species: Hu
Applications: ELISA
Species: Hu, Mu
Applications: IHC
Species: Hu, Mu
Applications: Flow-IC, Flow, ICC/IF, IHC, IHC-Fr, IHC-P, IP, WB
Species: Hu
Applications: BA
Species: Bv, Ca, Ch, Eq, Hu, Mu, Po, Rt
Applications: ICC/IF, IHC, IHC-Fr, IHC-P, WB
Species: Hu
Applications: BA
Species: Mu
Applications: CyTOF-ready, Flow, ICC, IHC, WB
Species: Hu, Mu, Rt, Xp(-), Ye
Applications: CyTOF-ready, ELISA, Flow-IC, Flow, ICC/IF, IHC, IHC-Fr, IHC-P, IP, WB
Species: Mu
Applications: Dual ISH-IHC, IHC, WB
Species: Rt
Applications: ELISA
Publications for CD117/c-kit ELISA Kit (NBP3-06960) (0)
There are no publications for CD117/c-kit ELISA Kit (NBP3-06960).
By submitting your publication information earn gift cards and discounts for future purchases.
Reviews for CD117/c-kit ELISA Kit (NBP3-06960) (0)
There are no reviews for CD117/c-kit ELISA Kit (NBP3-06960).
By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
- Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
- Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen
Product General Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
FAQs for CD117/c-kit ELISA Kit (NBP3-06960). (Showing 1 - 1 of 1 FAQ).
-
What is the difference between the Quantikine and Duoset ELISA kits?
- Our Quantikine kits are fully optimized and validated for the sample types listed on the product specific webpage and datasheet, as this can vary between kits. Each kit is supplied ready to use with one pre-coated 96-well plate, a detection antibody directly conjugated to HRP, and all other necessary reagents. These kits are ideal for researchers who want the convenience of a ready to use and optimized ELISA product. Some of these kits are also available prepackaged in larger 6 and 50 plate sizes.Our DuoSet Kits, in contrast, are ELISA development kits containing the capture and detection antibody, the mass-value calibrated standard, and streptavidin-HRP to prepare approximately 5 or 15 plates. Ancillary reagents will need to be used/purchased, and for most kits, we will recommend one of our Ancillary Reagent Kits, which contain the reagents we use ourselves in-house. DuoSet kits are validated only for cell culture supernatant samples and therefore require further development and validation for accurate measurement in more complex samples such as serum and plasma. Our DuoSet Kits offer an economical, flexible alternative for the experienced ELISA user.