Rat ACE/CD143 ELISA Kit (Colorimetric) Summary
| Specificity |
This kit recognizes Rat ACE in samples. No Significant cross-reactivity or interference between Rat ACE and analogues was observed. |
| Standard Curve Range |
0.31 - 20 ng/mL |
| Sensitivity |
0.19 ng/mL |
| Assay Type |
Sandwich-ELISA |
| Inter-Assay |
CV% < 4.91% |
| Intra-Assay |
CV% < 4.28% |
| Spike Recovery |
87-111% |
| Sample Volume |
100 uL |
| Kit Type |
ELISA Kit (Colorimetric) |
| Gene |
ACE |
Applications/Dilutions
Packaging, Storage & Formulations
| Storage |
Storage of components varies. See protocol for specific instructions. |
Kit Components
|
Components
|
- Biotinylated Detection Ab Diluent
- Concentrated Biotinylated Detection Ab (100x)
- Concentrated HRP Conjugate (100x)
- Concentrated Wash Buffer (25x)
- HRP Conjugate Diluent
- Micro ELISA Plate (Dismountable)
- Plate Sealer
- Product Manual
- Reference Standard
- Sample Diluent
- Stop Solution
- Substrate Reagent
|
Alternate Names for Rat ACE/CD143 ELISA Kit (Colorimetric)
Background
ACE converts angiotensin I to angiotensin II by release of the terminal His-Leu, this results in an increase of the vasoconstrictor activity of angiotensin. Also able to inactivate bradykinin, a potent vasodilatator. ACE exists in two forms, a 170KD somatic form and a 90KD germinal form. The somatic form is expressed by endothelial cells (especially those of lung capillaries and arterioles), epithelial cells (especially in proximal renal tubules and small intestine), by some neuronal cells and variably by some macrophages and T lymphocytes. The germinal form is expressed by spermatozoa.
Limitations
This product is for research use only and is not approved for use in humans or in clinical diagnosis. ELISA Kits are
guaranteed for 6 months from date of receipt.
Customers Who Viewed This Item Also Viewed...
Species: Hu, Mu, Rt
Applications: ICC/IF, IHC, IHC-P, WB
Species: Hu
Applications: IHC, IP, Neut, WB
Species: Hu
Applications: WB
Species: Hu
Applications: ELISA
Species: Am, Ca, Gp, Hu, Mu, Po, Rb, Rt, Sh
Applications: Flow, ICC/IF, IHC, IHC-Fr, IHC-P, IP, Simple Western, WB
Species: Hu, Mu, Rt
Applications: ELISA, ICC/IF, IHC, IHC-P, WB
Species: Mu
Applications: ELISA(Cap), ELISA(Det), ELISA(Sta), IHC, IP, WB
Species: Ca, Hu, Mu, Po, Pm, Rt(-)
Applications: Dual ISH-IHC, ICC/IF, IHC, IHC-Fr, IHC-P, IP, KO, PLA, WB
Species: Bv, Hu, Mu
Applications: ICC, IHC
Species: Hu
Applications: CyTOF-ready, Dual ISH-IHC, ICC, IHC, ICFlow, Simple Western, WB
Species: Hu, Mu, Rb, Rt
Applications: ELISA, ICC/IF, IHC, IHC-P, WB
Species: Hu, Mu
Applications: ICC, Simple Western, WB
Species: Ha, Hu, Mu, Rt
Applications: Block, Flow, IHC, IP, Simple Western, WB
Species: Hu
Applications: ICC/IF, WB
Species: Hu
Applications: BA
Species: Ha, Hu, Mu, Rt
Applications: ELISA, ICC/IF, KD, WB
Species: Hu, Mu
Applications: IHC, IHC-P, Simple Western, WB
Species: Hu, Pm, Mu, Rt
Applications: ChIP, ELISA, Flow, ICC/IF, IHC, IHC-P, IP, KD, PAGE, Single-Cell Western, WB
Publications for ACE/CD143 ELISA Kit (NBP2-78732) (0)
There are no publications for ACE/CD143 ELISA Kit (NBP2-78732).
By submitting your publication information earn gift cards and discounts for future purchases.
Reviews for ACE/CD143 ELISA Kit (NBP2-78732) (0)
There are no reviews for ACE/CD143 ELISA Kit (NBP2-78732).
By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
- Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
- Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen
Product General Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
FAQs for ACE/CD143 ELISA Kit (NBP2-78732). (Showing 1 - 1 of 1 FAQ).
-
What is the difference between the Quantikine and Duoset ELISA kits?
- Our Quantikine kits are fully optimized and validated for the sample types listed on the product specific webpage and datasheet, as this can vary between kits. Each kit is supplied ready to use with one pre-coated 96-well plate, a detection antibody directly conjugated to HRP, and all other necessary reagents. These kits are ideal for researchers who want the convenience of a ready to use and optimized ELISA product. Some of these kits are also available prepackaged in larger 6 and 50 plate sizes.Our DuoSet Kits, in contrast, are ELISA development kits containing the capture and detection antibody, the mass-value calibrated standard, and streptavidin-HRP to prepare approximately 5 or 15 plates. Ancillary reagents will need to be used/purchased, and for most kits, we will recommend one of our Ancillary Reagent Kits, which contain the reagents we use ourselves in-house. DuoSet kits are validated only for cell culture supernatant samples and therefore require further development and validation for accurate measurement in more complex samples such as serum and plasma. Our DuoSet Kits offer an economical, flexible alternative for the experienced ELISA user.
Additional ACE/CD143 Products
Research Areas for ACE/CD143 ELISA Kit (NBP2-78732)
Find related products by research area.
|
Blogs on ACE/CD143