Human TBK1 - Ready-To-Use ELISA Kit (Colorimetric) Summary
| Description |
The Ready-To-Use ELISA kit offers pre-diluted detection reagents and a shorter experimental time. Assay Length: 3 hours |
| Standard Curve Range |
0.312 - 20 ng/mL (example only; lot dependent) |
| Sensitivity |
0.112 ng/mL (example only; lot dependent) |
| Assay Type |
Sandwich ELISA |
| Inter-Assay |
%CV < 12 (example only; lot dependent) |
| Intra-Assay |
%CV < 10 (example only; lot dependent) |
| Sample Volume |
100 uL |
| Kit Type |
ELISA Kit (Colorimetric) |
| Gene |
TBK1 |
Applications/Dilutions
Packaging, Storage & Formulations
| Storage |
Storage of components varies. See protocol for specific instructions. |
Kit Components
|
Components
|
- Detection Solution A
- Detection Solution B
- Instruction manual
- Plate sealer for 96 wells
- Pre-coated 96T strip plate
- Standard Diluent
- Standard
- Stop Solution
- TMB Substrate
- Wash Buffer (30 x concentrate)
|
Alternate Names for Human TBK1 - Ready-To-Use ELISA Kit (Colorimetric)
Background
NFkappaB-activating kinase (NAK) also known as TANK binding kinase-1 (TBK1) or tumor necrosis factor receptor associated factor 2-associated kinase (T2K) is a serine/threonine protein that belongs to the IkB kinase (IKK) family (1). Similar to IKK alpha and beta (2), NAK induces IkB degradation and NF-kB activity. NAK is activated by phorbol ester tumour promoters and growth factors, whereas catalytically inactive NAK specifically inhibits activation of NF-kB by protein kinase C-epsilon (PKCepsilon). NAK specifically phosphorylates IkB alpha on Serine 36 and NFkB subunit RelA (p65) on Serine 536 (3). NAK is also known to interact with TANK, TRAF-2 and TRIF (4).
Limitations
This product is for research use only and is not approved for use in humans or in clinical diagnosis. ELISA Kits are
guaranteed for 6 months from date of receipt.
Customers Who Viewed This Item Also Viewed...
Species: Hu, Mu, Rt
Applications: Flow, ICC/IF, IHC, IHC-P, WB
Species: Mu, Po, Rt
Applications: IB, ICC/IF, IHC, IHC-P, IP, KD, Simple Western, WB
Species: Hu, Mu, Rt
Applications: ELISA, ICC/IF, IHC, IHC-P, WB
Species: Hu, Rb, Rt
Applications: Flow, IHC, IHC-P, KO, Simple Western, WB
Species: Bv, Hu, Ma, Mu, Po, Rt
Applications: B/N, ChIP, CyTOF-ready, DB, Dual ISH-IHC, ELISA(Cap), ELISA, Flow-CS, Flow-IC, Flow, ICC/IF, IHC, IHC-Fr, IHC-P, In vitro, KD, KO, PAGE, Simple Western, WB
Species: Ca, Hu, Mu
Applications: BA, B/N, Flow-IC, Flow, ICC/IF, IHC, IHC-P, WB
Species: Hu, Mu, Rt
Applications: ICC, WB
Species: Hu
Applications: BA
Species: Hu
Applications: BA
Species: Hu, Mu
Applications: IHC, IHC-P, PEP-ELISA, WB
Species: Hu, Mu, Rt, Ze
Applications: Flow, ICC/IF, IHC, IHC-P, IP, WB
Species: Hu, Mu, Rt
Applications: IHC, IHC-P, IP, WB
Species: Hu, Mu, Rt
Applications: CyTOF-ready, Flow, IB, ICC/IF, IHC, IHC-P, IP, Simple Western, WB
Species: Hu, Mu, Pm, Rt
Applications: ChIP, ChIP, Flow-IC, Flow, ICC/IF, IHC, IHC-Fr, IHC-P, IP, Simple Western, WB
Species: Hu, Mu, Rt
Applications: IHC, IHC-P, IP, WB
Species: Bv, Hu, Mu, Rt, Xp, Ye, Ze
Applications: BindInhib, B/N, ELISA, Flow, Func-Inh, IHC, In vitro, In vivo
Publications for TBK1 ELISA Kit (NBP3-40173) (0)
There are no publications for TBK1 ELISA Kit (NBP3-40173).
By submitting your publication information earn gift cards and discounts for future purchases.
Reviews for TBK1 ELISA Kit (NBP3-40173) (0)
There are no reviews for TBK1 ELISA Kit (NBP3-40173).
By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
- Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
- Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen
Product General Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
FAQs for TBK1 ELISA Kit (NBP3-40173). (Showing 1 - 7 of 7 FAQ).
-
What is the exact sequence this TBK1 antibody recognizes?
- The exact epitope of this TBK1 antibody is unknown because we do not perform epitope mapping. This TBK1 antibody was made against a synthetic peptide corresponding to aa 563-577 of human TBK1.
-
I'm using NAX (TBK1 antibody) why is my band different from the predicted molecular weight?
- While this TBK1 antibody is typically observed around 83 kDA variations including PTMs, relative charges and other experimental factors can affect where the band is observed.
-
We are looking to use your TBK1 antibody in simple western but need a good loading control also validated in simple western, which would you recommend?
- Our alpha tubulin loading control antibody (NB100-690) would be a good choice to use with the TBK1 antibody; it detects around 55 kDa and is validated in simple western.
-
Is there a smaller size of your TBK1 antibody?
- This TBK1 antibody is offered in a smaller 0.025 mg size.
-
Are there any publications where this TBK1 antibody was used in western blot for mouse?
- This TBK1 antibody was cited in a study looking at the relation between loss of TBK1 activity and increased susceptibility to LPS induced lethality. PMID 20651301
-
Cant this TBK1 antibody be conjugated to PE for FLOW?
- Although it has not been validated for flow we do offer this TBK1 antibody as a PE conjugate. If you would like to test in FLOW you may want to take advantage of our innovator's reward program.
-
What is the difference between the Quantikine and Duoset ELISA kits?
- Our Quantikine kits are fully optimized and validated for the sample types listed on the product specific webpage and datasheet, as this can vary between kits. Each kit is supplied ready to use with one pre-coated 96-well plate, a detection antibody directly conjugated to HRP, and all other necessary reagents. These kits are ideal for researchers who want the convenience of a ready to use and optimized ELISA product. Some of these kits are also available prepackaged in larger 6 and 50 plate sizes.Our DuoSet Kits, in contrast, are ELISA development kits containing the capture and detection antibody, the mass-value calibrated standard, and streptavidin-HRP to prepare approximately 5 or 15 plates. Ancillary reagents will need to be used/purchased, and for most kits, we will recommend one of our Ancillary Reagent Kits, which contain the reagents we use ourselves in-house. DuoSet kits are validated only for cell culture supernatant samples and therefore require further development and validation for accurate measurement in more complex samples such as serum and plasma. Our DuoSet Kits offer an economical, flexible alternative for the experienced ELISA user.