Human IL-3 ELISA Kit (Colorimetric) Summary
| Description |
This kit is a sandwich ELISA assay for the quantitative measurement of human IL-3 in serum, plasma, tissue homogenates and cell culture supernatants. The density of color is proportional to the amount of IL-3 captured from the samples. |
| Standard Curve Range |
15.6 - 1000 pg/mL |
| Sensitivity |
< 9.4 pg/mL |
| Assay Type |
Sandwich ELISA |
| Sample Volume |
0.1 mL |
| Kit Type |
ELISA Kit (Colorimetric) |
| Gene |
IL3 |
Applications/Dilutions
| Dilutions |
|
| Application Notes |
Detection Method: Absorbance (450 nm). Quantitative measurement of IL-3 in serum, plasma, tissue homogenates, culture supernatants and other biological fluids. |
Packaging, Storage & Formulations
Kit Components
|
Components
|
- Antibody dilution buffer
- Biotin- detection antibody (Concentrated)
- HRP-Streptavidin Conjugate (SABC)
- Lyophilized Standard
- Microplate: 96 wells
- Plate sealers
- SABC dilution buffer
- Sample / Standard dilution buffer
- Stop Solution
- TMB substrate
- Wash buffer (25X)
|
Alternate Names for Human IL-3 ELISA Kit (Colorimetric)
Background
Interleukin 3 is a pleiotropic factor produced primarily by activated T cells that can stimulate the proliferation and differentiation of pluripotent hematopoietic stem cells as well as various lineage committed progenitors. In addition, IL-3 also affects the functional activity of mature mast cells, basophils, eosinophils and macrophages. Because of its multiple functions and targets, it was originally studied under different names, including mast cell growth factor, P-cell stimulating factor, burst promoting activity, multi-colony stimulating factor, thy-1 inducing factor and WEHI-3 growth factor. In addition to activated T cells, other cell types such as human thymic epithelial cells, activated murine mast cells, murine keratinocytes and neurons/astrocytes can also produce IL-3. At the amino acid sequence level, mature human and murine IL-3 share only 29% sequence identity. Consistent with this lack of homology, IL-3 activity is highly species-specific and human IL-3 does not show activity on murine cells. IL-3 exerts its biological activities through binding to specific cell surface receptors. The high affinity receptor responsible for IL-3 signaling is composed of at least two subunits, an IL-3 specific alpha chain which binds IL-3 with low affinity and a common beta chain that is shared by the IL-5 and GM-CSF high-affinity receptors. Although the beta chain itself does not bind IL-3, it confers high-affinity IL-3 binding in the presence of the alpha chain. Receptors for IL-3 are present on bone marrow progenitors, macrophages, mast cells, eosinophils, megakaryocytes, basophils and various myeloid leukemic cells.
Limitations
This product is for research use only and is not approved for use in humans or in clinical diagnosis. ELISA Kits are
guaranteed for 6 months from date of receipt.
Customers Who Viewed This Item Also Viewed...
Species: Hu
Applications: BA
Species: Hu
Applications: BA
Species: Hu
Applications: BA
Species: Mu
Applications: ELISA
Species: Hu
Applications: BA
Species: Hu
Applications: BA
Species: Mu
Applications: ELISA
Species: Mu
Applications: ELISA
Species: Hu
Applications: BA
Species: Mu
Applications: ELISA(Cap), ELISA(Det), ELISA(Sta), Neut, WB
Species: Mu
Applications: ELISA(Cap), ELISA(Det), ELISA(Sta), Neut, WB
Species: Rt
Applications: IHC, WB
Species: Hu
Applications: BA
Species: Hu
Applications: BA
Species: Hu
Applications: Flow, ICC/IF, IHC, IHC-P
Species: Mu
Applications: BA
Species: Hu
Applications: ELISA
Species: Hu
Applications: BA
Species: Hu
Applications: CyTOF-ready, ELISA, Flow, ICC/IF, IHC, IHC-P, PA, WB
Species: Hu
Applications: ELISA
Publications for IL-3 ELISA Kit (NBP2-50063) (0)
There are no publications for IL-3 ELISA Kit (NBP2-50063).
By submitting your publication information earn gift cards and discounts for future purchases.
Reviews for IL-3 ELISA Kit (NBP2-50063) (0)
There are no reviews for IL-3 ELISA Kit (NBP2-50063).
By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
- Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
- Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen
Product General Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
FAQs for IL-3 ELISA Kit (NBP2-50063). (Showing 1 - 1 of 1 FAQ).
-
What is the difference between the Quantikine and Duoset ELISA kits?
- Our Quantikine kits are fully optimized and validated for the sample types listed on the product specific webpage and datasheet, as this can vary between kits. Each kit is supplied ready to use with one pre-coated 96-well plate, a detection antibody directly conjugated to HRP, and all other necessary reagents. These kits are ideal for researchers who want the convenience of a ready to use and optimized ELISA product. Some of these kits are also available prepackaged in larger 6 and 50 plate sizes.Our DuoSet Kits, in contrast, are ELISA development kits containing the capture and detection antibody, the mass-value calibrated standard, and streptavidin-HRP to prepare approximately 5 or 15 plates. Ancillary reagents will need to be used/purchased, and for most kits, we will recommend one of our Ancillary Reagent Kits, which contain the reagents we use ourselves in-house. DuoSet kits are validated only for cell culture supernatant samples and therefore require further development and validation for accurate measurement in more complex samples such as serum and plasma. Our DuoSet Kits offer an economical, flexible alternative for the experienced ELISA user.
Additional IL-3 Products
Research Areas for IL-3 ELISA Kit (NBP2-50063)
Find related products by research area.
|
Blogs on IL-3