Human Phospho-VEGFR3/Flt-4 DuoSet IC ELISA, 2 Plate

Images

 
Lysates prepared from human VEGF R3 transfected NS0 cells (NS0-hVEGF R3) were diluted in a series and analyzed by (A) IP-Western blot and (B) this DuoSet IC ELISA. IPs were done using an anti-VEGF R3 monoclonal ...read more
The indicated amounts of recombinant extracellular domains of human VEGF R3 (Catalog #349-F4), human VEGF R1 (Catalog #321-FL), human VEGF R2 (Catalog #357-KD) or human Tie-2 (Catalog #313-TI) were added to 20 μg ...read more

Product Details

Summary
Reactivity HuSpecies Glossary
Applications ELISA
Conjugate
Biotin

Order Details

View Available Conjugates
Catalog# & Conjugate Size Price

Human Phospho-VEGFR3/Flt-4 DuoSet IC ELISA, 2 Plate Summary

Source
N/A
Assay Type
Solid Phase Sandwich ELISA
Inter-Assay
See PDF Datasheet for details
Intra-Assay
See PDF Datasheet for details
Spike Recovery
See PDF Datasheet for details
Sample Volume
See PDF Datasheet for details
Gene
FLT4

Applications/Dilutions

Dilutions
  • ELISA
Application Notes
No significant interference observed with available related molecules.
Publications
Read Publications using DYC2724-2.

Packaging, Storage & Formulations

Storage
Store the unopened product at 2 - 8 °C. Do not use past expiration date.

Notes

This product is produced by and ships from R&D Systems, Inc., a Bio-Techne brand.

Alternate Names for Human Phospho-VEGFR3/Flt-4 DuoSet IC ELISA, 2 Plate

  • EC 2.7.10
  • EC 2.7.10.1
  • FLT4
  • Flt-4
  • fms-related tyrosine kinase 4
  • LMPH1A
  • PCLFLT41
  • soluble VEGFR3 variant 1
  • soluble VEGFR3 variant 2
  • soluble VEGFR3 variant 3
  • Tyrosine-protein kinase receptor FLT4
  • vascular endothelial growth factor receptor 3
  • VEGF R3
  • VEGFR3
  • VEGFR-3
  • VEGFR3Fms-like tyrosine kinase 4

Background

VEGF R1 (Flt-1), VEGF R2 (KDR/Flk-1), and VEGF R3 (Flt-4) belong to the class III subfamily of receptor tyrosine kinases (RTKs). All three receptors contain seven immunoglobulin-like repeats in their extracellular domain and kinase insert domains in their intracellular region. They are best known for regulating VEGF family-mediated vasculogenesis, angiogenesis, and lymphangiogenesis. They are also mediators of neurotrophic activity and regulators of hematopoietic development. VEGF R2 is thought to be the primary inducer of VEGF-mediated blood vessel growth, while VEGF R3 plays a significant role in VEGF-C and VEGF-D-mediated lymphangiogenesis.

Customers Who Viewed This Item Also Viewed...

DVEC00
Species: Hu
Applications: ELISA
DVE00
Species: Hu
Applications: ELISA
AF644
Species: Mu
Applications: CyTOF-ready, Dual ISH-IHC, Flow, IHC, Neut, WB
DVED00
Species: Hu
Applications: ELISA
AF321
Species: Hu
Applications: Block, CyTOF-ready, Flow, IHC, WB
NBP1-90267
Species: Hu, Mu, Rt
Applications: ICC/IF, IHC,  IHC-P, WB
AF2125
Species: Mu
Applications: Dual ISH-IHC, IHC, WB
AF3244
Species: Mu
Applications: IHC, Simple Western, WB
AF3628
Species: Hu, Mu, Rt
Applications: CyTOF-ready, Flow, ICC, IHC, Simple Western, WB
NB110-41083
Species: Hu
Applications: ELISA, WB
MAB7265
Species: Mu
Applications: IHC, WB
DPG00
Species: Hu
Applications: ELISA
AF4117
Species: Rt
Applications: IHC, WB
DYC2724-2
Species: Hu
Applications: ELISA

Publications for VEGFR3/Flt-4 (DYC2724-2)(6)

We have publications tested in 2 confirmed species: Human, Transgenic Mouse.


Filter By Application
All Applications
Filter By Species
Human
(5)
Transgenic Mouse
(1)
All Species
Showing Publications 1 - 6 of 6.
Publications using DYC2724-2 Applications Species
Mondal, DK;Xie, C;Buraschi, S;Iozzo, RV; Decorin suppresses tumor lymphangiogenesis: A mechanism to curtail cancer progression bioRxiv : the preprint server for biology 2023-08-29 [PMID: 37693608] (Human) Human
A Dumond, C Montemagno, V Vial, R Grépin, G Pagès Anti-Vascular Endothelial Growth Factor C Antibodies Efficiently Inhibit the Growth of Experimental Clear Cell Renal Cell Carcinomas Cells, 2021-05-17;10(5):. 2021-05-17 [PMID: 34067671] (Human) Human
Proteolytic activation defines distinct lymphangiogenic mechanisms for VEGFC and VEGFD J Clin Invest, 2016-05-09;0(0):. 2016-05-09 [PMID: 27159393] (Human) Human
Harris , Nicole C, Davydova , Natalia, Roufail , Sally, Paquet-Fifield , Sophie, Paavonen , Karri, Karnezis , Tara, Zhang , You-Fang, Sato , Teruhiko, Rothacker , Julie, Nice , Edouard, Stacker , Steven A, Achen , Marc G The propeptides of VEGF-D determine heparin binding, receptor heterodimerization, and effects on tumor biology. J Biol Chem, 2013-02-12;288(12):8176-86. 2013-02-12 [PMID: 23404505] (Human) Human
Lara Planas-Paz, Boris Strilić, Axel Goedecke, Georg Breier, Reinhard Fässler, Eckhard Lammert Mechanoinduction of lymph vessel expansion The EMBO Journal 2012-02-15 [PMID: 22157817] (Human) Human
Schomber T, Zumsteg A, Strittmatter K, Crnic I, Antoniadis H, Littlewood-Evans A, Wood J, Christofori G Differential effects of the vascular endothelial growth factor receptor inhibitor PTK787/ZK222584 on tumor angiogenesis and tumor lymphangiogenesis. Mol. Cancer Ther., 2009-01-01;8(1):55-63. 2009-01-01 [PMID: 19139113] (Transgenic Mouse) Transgenic Mouse

Reviews for VEGFR3/Flt-4 (DYC2724-2) (0)

There are no reviews for VEGFR3/Flt-4 (DYC2724-2). By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
  • Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
  • Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen

Product General Protocols

Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.

FAQs for VEGFR3/Flt-4 (DYC2724-2). (Showing 1 - 1 of 1 FAQs).

  1. What is the difference between the Quantikine and Duoset ELISA kits?
    • Our Quantikine kits are fully optimized and validated for the sample types listed on the product specific webpage and datasheet, as this can vary between kits. Each kit is supplied ready to use with one pre-coated 96-well plate, a detection antibody directly conjugated to HRP, and all other necessary reagents. These kits are ideal for researchers who want the convenience of a ready to use and optimized ELISA product. Some of these kits are also available prepackaged in larger 6 and 50 plate sizes.Our DuoSet Kits, in contrast, are ELISA development kits containing the capture and detection antibody, the mass-value calibrated standard, and streptavidin-HRP to prepare approximately 5 or 15 plates. Ancillary reagents will need to be used/purchased, and for most kits, we will recommend one of our Ancillary Reagent Kits, which contain the reagents we use ourselves in-house. DuoSet kits are validated only for cell culture supernatant samples and therefore require further development and validation for accurate measurement in more complex samples such as serum and plasma. Our DuoSet Kits offer an economical, flexible alternative for the experienced ELISA user.

Additional VEGFR3/Flt-4 Products

Blogs on VEGFR3/Flt-4

There are no specific blogs for VEGFR3/Flt-4, but you can read our latest blog posts.

Customers Who Bought This Also Bought

Contact Information

Product PDFs

Review this Product

Be the first to review our Human Phospho-VEGFR3/Flt-4 DuoSet IC ELISA, 2 Plate and receive a gift card or discount.

Bioinformatics

Gene Symbol FLT4