After August 17, 2026, Novus Biologicals products and services will no longer be available on this website; you will access all products and services on rndsystems.com. Create your R&D Systems online account today.
HAF017). A specific band was detected for Corin at approximately 85 and 130 kDa (as indicated). This experiment was conducted under reducing conditions and using Immunoblot Buffer Group 1." >
HAF017). A specific band was detected for Corin at approximately 85 and 130 kDa (as indicated). This experiment was conducted under reducing conditions and using Immunoblot Buffer Group 1." title="Western blot shows lysates of human heart tissue. PVDF membrane was probed with 1 µg/mL of Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # af2209) followed by HRP-conjugated Anti-Goat IgG Secondary Antibody (Catalog # HAF017). A specific band was detected for Corin at approximately 85 and 130 kDa (as indicated). This experiment was conducted under reducing conditions and using Immunoblot Buffer Group 1." />
Western blot shows lysates of human heart tissue. PVDF membrane was probed with 1 µg/mL of Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # af2209) followed by HRP-conjugated Anti-Goat IgG ...read more
VC004). Before incubation with the primary antibody, tissue was subjected to heat-induced epitope retrieval using Antigen Retrieval Reagent-Basic (Catalog # CTS013). Tissue was stained using DAB (brown) and counterstained with hematoxylin (blue). Specific staining was localized to endothelial cells in canaliculi. View our protocol for IHC Staining with VisUCyte HRP Polymer Detection Reagents." >
VC004). Before incubation with the primary antibody, tissue was subjected to heat-induced epitope retrieval using Antigen Retrieval Reagent-Basic (Catalog # CTS013). Tissue was stained using DAB (brown) and counterstained with hematoxylin (blue). Specific staining was localized to endothelial cells in canaliculi. View our protocol for IHC Staining with VisUCyte HRP Polymer Detection Reagents." title="Corin was detected in immersion fixed paraffin-embedded sections of human liver using Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) at 3 µg/mL for 1 hour at room temperature followed by incubation with the Anti-Goat IgG VisUCyte™ HRP Polymer Antibody (Catalog # VC004). Before incubation with the primary antibody, tissue was subjected to heat-induced epitope retrieval using Antigen Retrieval Reagent-Basic (Catalog # CTS013). Tissue was stained using DAB (brown) and counterstained with hematoxylin (blue). Specific staining was localized to endothelial cells in canaliculi. View our protocol for IHC Staining with VisUCyte HRP Polymer Detection Reagents." />
Corin was detected in immersion fixed paraffin-embedded sections of human liver using Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) at 3 µg/mL for 1 hour at room temperature ...read more
VC004). Before incubation with the primary antibody, tissue was subjected to heat-induced epitope retrieval using Antigen Retrieval Reagent-Basic (Catalog # CTS013). Tissue was stained using DAB (brown) and counterstained with hematoxylin (blue). Specific staining was localized to cytoplasm in cardiomyocytes. View our protocol for IHC Staining with VisUCyte HRP Polymer Detection Reagents." >
VC004). Before incubation with the primary antibody, tissue was subjected to heat-induced epitope retrieval using Antigen Retrieval Reagent-Basic (Catalog # CTS013). Tissue was stained using DAB (brown) and counterstained with hematoxylin (blue). Specific staining was localized to cytoplasm in cardiomyocytes. View our protocol for IHC Staining with VisUCyte HRP Polymer Detection Reagents." title="Corin was detected in immersion fixed paraffin-embedded sections of human heart using Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) at 0.3 µg/mL for 1 hour at room temperature followed by incubation with the Anti-Goat IgG VisUCyte™ HRP Polymer Antibody (Catalog # VC004). Before incubation with the primary antibody, tissue was subjected to heat-induced epitope retrieval using Antigen Retrieval Reagent-Basic (Catalog # CTS013). Tissue was stained using DAB (brown) and counterstained with hematoxylin (blue). Specific staining was localized to cytoplasm in cardiomyocytes. View our protocol for IHC Staining with VisUCyte HRP Polymer Detection Reagents." />
Corin was detected in immersion fixed paraffin-embedded sections of human heart using Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) at 0.3 µg/mL for 1 hour at room temperature ...read more
MAB2209) coated on a Clear Polystyrene Microplate (Catalog # DY990). Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) was biotinylated and incubated with the protein captured on the plate. Detection of the standard curve was achieved by incubating Streptavidin-HRP (Catalog # DY998) followed by Substrate Solution (Catalog # DY999) and stopping the enzymatic reaction with Stop Solution (Catalog # DY994)." >
MAB2209) coated on a Clear Polystyrene Microplate (Catalog # DY990). Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) was biotinylated and incubated with the protein captured on the plate. Detection of the standard curve was achieved by incubating Streptavidin-HRP (Catalog # DY998) followed by Substrate Solution (Catalog # DY999) and stopping the enzymatic reaction with Stop Solution (Catalog # DY994)." title="Recombinant Human Corin protein was serially diluted 2-fold and captured by Rat Anti-Human Corin Monoclonal Antibody (Catalog # MAB2209) coated on a Clear Polystyrene Microplate (Catalog # DY990). Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) was biotinylated and incubated with the protein captured on the plate. Detection of the standard curve was achieved by incubating Streptavidin-HRP (Catalog # DY998) followed by Substrate Solution (Catalog # DY999) and stopping the enzymatic reaction with Stop Solution (Catalog # DY994)." />
Recombinant Human Corin protein was serially diluted 2-fold and captured by Rat Anti-Human Corin Monoclonal Antibody (Catalog # ...read more
3560-ZN) was serially diluted and captured by Rat Anti-Human Corin Monoclonal Antibody (Catalog # MAB2209) coated on a Clear Polystyrene Microplate (Catalog # DY990). Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) was biotinylated and incubated with the protein captured on the plate. Detection of the standard curve was achieved by incubating Streptavidin-HRP (Catalog # DY998)" >
3560-ZN) was serially diluted and captured by Rat Anti-Human Corin Monoclonal Antibody (Catalog # MAB2209) coated on a Clear Polystyrene Microplate (Catalog # DY990). Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) was biotinylated and incubated with the protein captured on the plate. Detection of the standard curve was achieved by incubating Streptavidin-HRP (Catalog # DY998)" title="Recombinant Human Cytosol Nonspecific Dipeptidase (CNDP2)/CPGL (Catalog # 3560-ZN) was serially diluted and captured by Rat Anti-Human Corin Monoclonal Antibody (Catalog # MAB2209) coated on a Clear Polystyrene Microplate (Catalog # DY990). Goat Anti-Human Corin Antigen Affinity-purified Polyclonal Antibody (Catalog # AF2209) was biotinylated and incubated with the protein captured on the plate. Detection of the standard curve was achieved by incubating Streptavidin-HRP (Catalog # DY998)" />
Recombinant Human Cytosol Nonspecific Dipeptidase (CNDP2)/CPGL (Catalog # 3560-ZN) was serially diluted and ...read more
Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
12 months from date of receipt, -20 to -70 °C as supplied.
1 month, 2 to 8 °C under sterile conditions after reconstitution.
6 months, -20 to -70 °C under sterile conditions after reconstitution.
Buffer
Lyophilized from a 0.2 μm filtered solution in PBS with Trehalose. *Small pack size (SP) is supplied either lyophilized or as a 0.2 µm filtered solution in PBS.
Preservative
No Preservative
Concentration
LYOPH
Reconstitution Instructions
Reconstitute at 0.2 mg/mL in sterile PBS.
Notes
This product is produced by and ships from R&D Systems, Inc., a Bio-Techne brand.
Alternate Names for Corin Antibody [Unconjugated]
ATC2
atrial natriuteric peptide-converting enzyme
Corin
corin, serine peptidase
EC 3.4.21
EC 3.4.21.-
heart specific serine proteinase
Heart-specific serine proteinase ATC2
MGC119742
pro-ANP-convertase
Pro-ANP-Converting Enzyme
PRSC
serine protease
Transmembrane protease serine 10
Background
Corin is a type II transmembrane serine protease expressed predominantly in cardiomyocytes. It converts pro arterial natriuretic peptide (pro-ANP) to ANP.
Limitations
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.
The concentration calculator allows you to quickly calculate the volume, mass or concentration of your vial. Simply enter your mass, volume, or concentration values for your reagent and the calculator will determine the rest.
=
÷
Review this Product
Be the first to review our Corin Antibody [Unconjugated] and receive a gift card or discount.