Human P2X7/P2RX7 ELISA Kit (Colorimetric)

Images

 
ELISA: Human P2X7/P2RX7 ELISA Kit (Colorimetric) [NBP3-40286] - Standard Curve Reference

Product Details

Summary
Reactivity HuSpecies Glossary
Applications ELISA
Suitable Sample Type
Tissue homogenates, cell lysates and other biological fluids
Standard Curve Range
0.312 - 20 ng/mL (example only; lot dependent)
Sensitivity
0.112 ng/mL (example only; lot dependent)

Order Details

Human P2X7/P2RX7 ELISA Kit (Colorimetric) Summary

Description
Assay Length: 4.5 hours
Standard Curve Range
0.312 - 20 ng/mL (example only; lot dependent)
Sensitivity
0.112 ng/mL (example only; lot dependent)
Assay Type
Sandwich ELISA
Inter-Assay
%CV < 12 (example only; lot dependent)
Intra-Assay
%CV < 10 (example only; lot dependent)
Sample Volume
100 uL
Kit Type
ELISA Kit (Colorimetric)
Gene
P2RX7

Applications/Dilutions

Dilutions
  • ELISA

Packaging, Storage & Formulations

Storage
Storage of components varies. See protocol for specific instructions.

Kit Components

Components
  1. Detection Reagent A
  2. Detection Reagent B
  3. Diluent Buffer
  4. Instruction manual
  5. Plate sealer for 96 wells
  6. Pre-coated 96T strip plate
  7. Standard
  8. Stop Solution
  9. TMB Substrate
  10. Wash Buffer (30 x concentrate)

Alternate Names for Human P2X7/P2RX7 ELISA Kit (Colorimetric)

  • ATP receptor
  • MGC20089
  • P2RX7
  • P2X purinoceptor 7
  • P2X7
  • P2X7P2X7 receptor
  • P2X7R
  • P2Z receptor
  • purinergic receptor P2X, ligand-gated ion channel, 7
  • purinergic receptor P2X7 variant A
  • Purinergic receptor

Background

FUNCTION: Receptor for ATP that acts as a ligand gated ion channel. Responsible for ATP-dependent lysis of macrophages through the formation of membrane pores permeable to large molecules. Could function in both fast synaptic transmission and the ATP-mediated lysis of antigen-presenting cells.; Subcellular location: Membrane; Multi-pass membrane protein.

Limitations

This product is for research use only and is not approved for use in humans or in clinical diagnosis. ELISA Kits are guaranteed for 6 months from date of receipt.

Customers Who Viewed This Item Also Viewed...

NBP1-92239
Species: Hu
Applications: ICC/IF, IHC,  IHC-P, WB
NBP1-32870
Species: Ch, Hu
Applications: IHC,  IHC-P, IP, KD, WB
AF5866
Species: Hu
Applications: IHC, WB
NBP3-48674
Species: Hu, Mu, Rt, Ze
Applications: ICC/IF, IHC,  IHC-P, WB
NBP2-19655
Species: Hu, Mu
Applications: ICC/IF, IHC,  IHC-P, WB
NBP2-33848
Species: Hu
Applications: IHC,  IHC-P
NBP3-48734
Species: Hu, Mu
Applications: ICC/IF, IHC,  IHC-P
DYC1825-2
Species: Hu, Mu, Rt
Applications: ELISA
NB100-56565
Species: Hu, Mu, Rt
Applications: ICC/IF, IHC, IHC-Fr,  IHC-P, Simple Western, WB
AF1230
Species: Hu, Mu, Rt
Applications: IHC, KO, WB
201-LB
Species: Hu
Applications: BA
NBP3-35187
Species: Hu, Mu, Rt
Applications: ELISA, ICC/IF, WB
MAB7097
Species: Hu, Mu, Rt
Applications: WB
7625
Species: Mu
Applications: ELISA
NBP3-40286
Species: Hu
Applications: ELISA

Publications for P2X7/P2RX7 ELISA Kit (NBP3-40286) (0)

There are no publications for P2X7/P2RX7 ELISA Kit (NBP3-40286).
By submitting your publication information earn gift cards and discounts for future purchases.

Reviews for P2X7/P2RX7 ELISA Kit (NBP3-40286) (0)

There are no reviews for P2X7/P2RX7 ELISA Kit (NBP3-40286). By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
  • Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
  • Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen

Product General Protocols

Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.

FAQs for P2X7/P2RX7 ELISA Kit (NBP3-40286). (Showing 1 - 1 of 1 FAQ).

  1. What is the difference between the Quantikine and Duoset ELISA kits?
    • Our Quantikine kits are fully optimized and validated for the sample types listed on the product specific webpage and datasheet, as this can vary between kits. Each kit is supplied ready to use with one pre-coated 96-well plate, a detection antibody directly conjugated to HRP, and all other necessary reagents. These kits are ideal for researchers who want the convenience of a ready to use and optimized ELISA product. Some of these kits are also available prepackaged in larger 6 and 50 plate sizes.Our DuoSet Kits, in contrast, are ELISA development kits containing the capture and detection antibody, the mass-value calibrated standard, and streptavidin-HRP to prepare approximately 5 or 15 plates. Ancillary reagents will need to be used/purchased, and for most kits, we will recommend one of our Ancillary Reagent Kits, which contain the reagents we use ourselves in-house. DuoSet kits are validated only for cell culture supernatant samples and therefore require further development and validation for accurate measurement in more complex samples such as serum and plasma. Our DuoSet Kits offer an economical, flexible alternative for the experienced ELISA user.

Additional P2X7/P2RX7 Products

Research Areas for P2X7/P2RX7 ELISA Kit (NBP3-40286)

Find related products by research area.

Blogs on P2X7/P2RX7

There are no specific blogs for P2X7/P2RX7, but you can read our latest blog posts.

Customers Who Bought This Also Bought

Contact Information

Product PDFs

Review this Product

Be the first to review our Human P2X7/P2RX7 ELISA Kit (Colorimetric) and receive a gift card or discount.

Bioinformatics

Gene Symbol P2RX7