Immunohistochemistry (IHC) Detection

Direct or indirect detection methods can be used to produce a fluorescent or chromogenic signal for protein detection. In direct detection, the primary antibody specific for the target molecule is directly labeled. Indirect detection uses an unconjugated primary antibody. Instead, a secondary antibody raised against the species of the primary antibody carries the label. The indirect method is often the preferred method in immunohistochemistry (IHC) staining experiments due to signal amplification courtesy of secondary antibodies. Common detection labels for visualization include fluorescent labels which emit light, and enzymes which convert soluble substrates to insoluble, chromogenic end products. Both chromogenic and fluorescent detection methods have unique advantages and disadvantages. Choosing which type of detection to use is contingent on the experimental details.

Chromogenic Detection vs. Fluorescent Detection

 

Advantages

Disadvantages

Fluorescent Detection
  • Easier Multiplexing: More colors and narrower emission spectra than chromogenic dyes.
  • Better Target Co-localization: Fluorescent dyes allow separate identification of co-localized targets.
  • Higher Dynamic Range: Easier to visualize rare and high abundant targets on the same slide.
  • Fewer Steps: No step for substrate addition.
  • Lower sensitivity: Enzyme conjugated antibodies can be amplified via indirect detection to increase sensitivity (See below)
  • Susceptible to Photobleaching: Exposure to light may diminish fluorescent signal over time.
Chromogenic Detection
  • Greater Sensitivity: Signal amplification via indirect chromogenic detection (see below) increases signal strength.
  • Longer Lasting Signal: Chromogenic stains are more resistant to photobleaching than fluorochromes.
  • Difficult Target Co-localization: Difficult to distinguish mixed color from single color when targets co-localize.
  • Narrower Dynamic Range: Difficult to visualize rare and high abundant targets on the same slide.
  • Difficult Multiplexing: Fewer colors and broader emission spectra than fluorescent dyes.



Fluorescent Detection

How does fluorescent detection work? Fluorescent detection requires a fluorochrome conjugated antibody to emit light when stimulated with a light of a shorter wavelength.

Can I use a conjugated primary antibody in my IF experiment? In the indirect method of detection, multiple secondary antibodies can bind to a single primary antibody. Because of its ability to amplify signal, indirect detection is often the method of choice for IHC/IF experiments. Staining tissue antigen with a primary conjugated antibody is only recommended for highly abundant tissue antigens where signal amplification is not necessary.

Can I run multiplex IHC using fluorescent detection? The large number of available fluorochromes allow the simultaneous detection of multiple targets due to their ability to emit light at unique wavelengths. Fluorochromes should be chosen carefully in multiplex experiments to minimize spectral overlap. In addition, multiplex fluorescent experiments should be designed to limit cross-reactivity. By choosing primary antibodies from different host species, difficulties concerning cross reactivity can largely be ignored. In this case, species-specific secondary antibodies will recognize only one primary antibody.

Example of IHC Detection by Immunofluorescence (IF):

IHC detection by Immunofluorescence CD31 in Mouse Embryo

CD31/PECAM-1 in Mouse Embryo. CD31 staining using Goat Anti-Mouse/Rat CD31/PECAM 1 Antigen Affinity-purified Polyclonal Antibody (Catalog # AF3628).

IHC detection by Immunofluorescence GFAP in rat neurons

GFAP in Rat Neurons. GFAP (green) and Neurofilament Heavy (red) staining using Rabbit Anti-Rat GFAP Polyclonal Antibody (Catalog # NB300-141) and Chicken Anti-Rat NF-H Polyclonal Antibody (Catalog # NB300-217).


Chromogenic Detection

How does chromogenic detection work? Antigen expression is visualized in chromogenic detection when a soluble substrate is converted by an enzyme to an insoluble colored product that is deposited at the site of antigen expression. The enzymes horseradish peroxidase (HRP) and alkaline phosphatase are often used in chromogenic detection and function by converting 3,3' diaminobenzidine (DAB) and 3-amino-9-ethylcarbazole (AEC), into brown and red end products, respectively.

Should I use DAB, AEC, or a different chromogen? DAB is more popular than AEC due its longevity and resistance to fading when exposed to light. If multiplexing, it is recommended to choose chromogens with opposing colors to limit spectral overlap.

Can I run multiplex IHC using chromogenic detection? Although visualization of multiple antigens is possible by chromogenic detection, the deposition of two colors on co-localized proteins may obscure results. Therefore, it is recommended to multiplex only when the antigens are confined to unique cellular locations. This will allow easier differentiation of each target.

Example of Chromogenic IHC Detection:
Chromogenic IHC detection survivin in human rectal cancer

Survivin in Human Rectal Cancer. Survivin staining using Rabbit Anti-Human Survivin Antigen Affinity-purified Polyclonal Antibody (Catalog # NB500-201).

Chromogenic IHC detection TBK1 in human skin

TBK1/NAK in Human Skin. TBK1 staining using Mouse Anti-Human TBK1 Monoclonal Antibody (Catalog # NBP1-52447).


Signal Amplification Using Chromogenic Detection

Avidin-Biotin Complex (ABC) Method

In the avidin-biotin complex (ABC) method, biotin conjugated secondary antibodies link tissue-bound primary antibodies with an avidin-biotin-peroxidase complex. The avidin molecule contains four binding sites for biotin. These binding sites enable complexes to form, where avidin molecules are linked together via the enzyme. A colorless substrate is then added and subsequently converted to a brown product by the peroxidase enzyme to mark the target antigen. The large complexes formed in the ABC method contain multiple copies of the reporter enzyme. Because of the high enzyme-to-antibody ratio, the ABC method increases sensitivity compared to direct conjugation of enzyme to the secondary antibody.

Avidin-Biotin Complex Method


Labeled Streptavidin-Biotin (LSAB) Method

Similar to the avidin-biotin complex (ABC) method, the labeled streptavidin-biotin (LSAB) method uses a biotin conjugated secondary antibody to link the primary antibody to a streptavidin-peroxidase complex. The advantage of this approach is the lack of need for the ABC complex and the overall smaller complex size. The smaller complex, compared to the ABC method, facilitates tissue penetration and can enhance sensitivity.

Labeled streptavidin-biotin method


Drawbacks to ABC and LSAB Methods

Despite the prevalence of streptavidin-biotin-based detection methods, these detection systems have intrinsic limitations. The presence of endogenous biotin in tissues can increase background significantly. Formalin fixation and paraffin embedding does significantly reduce the amount of endogenous biotin, but tissues with high expression of the molecule, such as the liver and kidney, can still exhibit residual activity. Blocking endogenous biotin can be effective at reducing background signal. Note that frozen tissue sections often exhibit higher amounts of endogenous biotin than FFPE sections, so non-biotin-based detection system should be considered if staining frozen tissue sections.

Polymer-Based Methods

In the polymer-based detection method, antibodies and enzymes are conjugated to a polymer backbone. The large number of antibodies and enzymes conjugated to the polymer enhance sensitivity and specificity compared to streptavidin-biotin-based systems. In addition to increased sensitivity, the polymer system decreases the number of steps in the IHC staining procedure, incorporating staining into one single step.

polymer based detection method


Summary of Signal Amplification Methods

 

Complex Formed

Advantages

ABC Method Avidin-biotin-enzyme ABC method
  • Greater sensitivity than traditional indirect detection.
LSAB Method Streptavidin-enzyme LSAB method
  • Greater sensitivity than traditional indirect detection.
  • Smaller complex size compared to ABC facilitates greater tissue penetration.
Polymer-based Method Polymer backbone- enzyme polymer based method
  • Greater sensitivity than ABC and LSAB.
  • Fewer steps than ABC and LSAB.

View Detection Reagents


Back to Epitope Retrieval