Lightning-Link Glucose Oxidase Antibody Labeling Kit


There are currently no images for Lightning-Link Glucose Oxidase Kit (706-0015).

Every product we sell is backed by Novus' 100% Guarantee. If you have used this product, please submit your images and reviews to earn reward points.

Product Details

Kit Type
Antibody Labeling Kit

Order Details

Lightning-Link Glucose Oxidase Antibody Labeling Kit Summary

Lightning-Link® is an innovative technology that enables direct labeling of proteins, peptides or other biomolecules for use in R&D applications, drug discovery and the development of diagnostic kits.

The researcher simply pipettes the biomolecule into a vial of lyophilized mixture containing the label of interest and incubates. Despite its apparent simplicity, the Lightning-Link® process is sophisticated and generates conjugates with performance characteristics identical to, or better than, those prepared with laborious multistep conjugation procedures.

  • 30 seconds hands-on time
  • No separation steps
  • No losses
  • Scalable technology
  • Easy to use antibody labeling kit
  • Antibody recovery is 100%
  • Applicable to Western Blotting, ELISA, Immuohistochemistry, Immunofluorescence, and FACS analysis
  • From 10ug up to 5mg

Glucose oxidase is an enzyme produced and purified from Aspergillus niger which catalyses the oxidation of glucose with the release of hydrogen peroxide. It's molecular weight is 80kDa, but it exists as a dimer of 160kDa Measurement of glucose by GOx is used in the food industry, in fermentation and, most importantly, as the basis of biosensors for the diagnosis of diabetes.
Kit Type
Antibody Labeling Kit

Packaging, Storage & Formulations

Store at -20C. Avoid freeze-thaw cycles.


Read Publications using 706-0015.

Kit Components

  1. Glass vial(s) of Lightning-Link mix (1 or 3 vials, depending on pack size)
  2. 1 vial of LL-GOx Modifier reagent
  3. 1 vial of LL-GOx Quencher reagent


Learn more about Lightning-Link™ Conjugation Kits by reading FAQs

For more information please check out these useful links!
Fluorescent Labels Poster
Antibody Labeling Guide
Antibody Purification Guide

Lightning Link® is a registered trademark of Innova Biosciences.


This product is for research use only and is not approved for use in humans or in clinical diagnosis. Kits are guaranteed for 6 months from date of receipt.

Publications for Lightning-Link Glucose Oxidase Kit (706-0015)(4)

Reviews for Lightning-Link Glucose Oxidase Kit (706-0015) (0)

There are no reviews for Lightning-Link Glucose Oxidase Kit (706-0015). By submitting a review earn points towards our Rewards Program.
  • 250 points for product review
  • 500 additional points for an image with your product review
  • Double points (500) if you are the first to review this product
  • Double points (1000) if you are the first to review this product with an image

Product General Protocols

View specific protocols for Lightning-Link Glucose Oxidase Kit (706-0015): Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.

FAQs for Lightning-Link Glucose Oxidase Kit (706-0015). (Showing 1 - 8 of 8 FAQs).

  1. Can I label a peptide/protein/antibody other than IgG?
    • Yes. The Lightning-Link® technology works by targeting free amine groups on your target, meaning it can be used to label most biomolecules.As the protocols provided were optimized for labeling IgGs, we would recommend you adjust the amount of material you add to the Lighting-Link® vial to allow for molecular weight difference. This should be done without changing the volume added to the vial, as this could affect the conjugation efficiency. As a rough guideline, we would recommend changing the amount of material proportionally to the size difference with IgGs. An average IgG is about 160kD, therefore for a target that is half the size of an antibody (about 80kD), add half as much to the vial. Please note this is only a guideline and the best amount for your assay should be determined experimentally; our 3x10ug kits enable you to do this using small amounts of material and therefore at a low cost.
  2. Do I need a wash or desalt step?
    • One of the advantages of the Lightning-Link® technology compared to traditional labeling methods is that conjugate purification is not required. The Lightning-Link® reactions are highly efficient, and the kits have been optimized so that, provided the protocols are followed, there should be only a very low amount of free label left at the end of the conjugation. Any remaining free label would have its reactive 'Lightning-Link®' groups blocked by the Quencher provided in the kit, and would then be washed away during the relevant wash step of your application.
  3. Do my antibody and buffer fit the requirements?
    • Your antibody should be purified (affinity purification is preferred), as other molecules with free amine groups will interfere with the reaction, resulting in a poor quality conjugate. A suitable method of purification should be used (such as affinity or Protein A/G). Please note that 0.2/0.22 um filtration is a method of sterilization, not purification.Your biomolecule should also be in a suitable, 10-50mM amine free buffer (e.g. MES, MOPS, HEPES, PBS), pH range 6.5 to 8.5 and not in any of the following: ascites fluid, serum or tissue culture supernatant. It should not contain any additives such as Azide, BSA, Tris or Glycine at a concentration of >0.1%.The amount of antibody (IgG) you should add to the Lightning-Link® vial usually corresponds to the kit size your purchased (for example: a 3x100ug kit enable you to label 3 lots of 100ug antibody) and the volume added should also match (eg: 100ul), meaning the ideal concentration is of 1mg/ml. For other biomolecule, the amount added should be adjusted by changing your concentration (see above).NOTE: The amount and volume of antibody recommended above are for all Lightning-Link• kits offered by Innova Biosciences, with the exception of RPE and PE tandem dyes. For more details on the recommendations specific to these dyes, please consult the protocols available on each product page.
  4. How many labels will bind to my biomolecule?
    • It is difficult to give a precise answer to this as the result will vary from antibody to antibody (or other protein). Traditional labelling techniques often have F/P ratios in the range of 4-7:1, and our comparative data for staining with antibodies labelled with Lightning Link shows similar staining intensity. The ratio of dye to antibody is only ever an average for the population of labelled molecules, as individual molecules may have different amount of dye incorporated into them.
  5. How stable will my new conjugate be?
    • The Lightning-Link® chemistry joins the label to the antibody via a uni directional stable, covalent bond. The stability of your conjugate will therefore be dependent on your antibody and label of choice. In our in-house studies, conjugates made with our Lightning-Link® kits were fully active after more than 18 months' storage, undiluted, at 4 degrees C. Conjugates stored in 50% glycerol at -20 degrees C were found to be even more stable (several years). Please see below for advice on storage conditions. Please note that tandem dye stability is lower than the other dyes'. Tandem conjugates are fully stable for about 3 months at 4 degrees C.
  6. What are the best storage conditions for my new conjugate?
    • TA new conjugate can be stored for 12-18 months at 4 degrees C as long as the antibody will tolerate storage at 4 degrees C. As the bond between the antibody and dye is covalent and very stable, it should not degrade, therefore at 4 degrees C no additional preservatives are needed. The antibody is usually the least stable component of the conjugate so please check the antibody datasheet for storage recommendations. However, all conjugates can be stored in 50% glycerol at -20 degrees C which allows them to remain stable for 2 years. Please bear in mind that APC and RPE conjugates should never be stored at -20 degrees C on their own without glycerol. The dilution factor also has an effect. Storing the conjugate undiluted is recommended if possible; however, for HRP conjugates, if you wish to store at working concentrations (e.g. 1/10,000), this can be done using our LifeXtend HRP Conjugate Stabilizer/Diluent. Please note that the preservative sodium azide will inhibit HRP. We suggest that the optimal storage conditions for any conjugate are determined experimentally, using small aliquots of the conjugate.
  7. What can I do if my antibody formulation does not fit the requirements?
    • If your antibody buffer is not compatible with our kits, we have developed an AbSelect™ purification kit range that allows you to quickly and simply purify your antibody and is fully compatible with the Lightning-Link® kits.The appropriate kit to use depends on your particular sample (species, buffer, contaminants, volume,...). We have designed a handy flow chart on the AbSelect™ webpage to help you select a kit, but feel free to contact us if you require further guidance. Please consult the kit protocols to see the antibody amount/volume suitable for each kit.If your antibody is already purified but its concentration is too low, you can concentrate it by using our Antibody Concentration and Clean Up Kit. This kit can also be used to remove low molecular weight contaminants such as azide, tris or glycine by carrying out a buffer exchange into the buffer supplied in the kit, which is fully compatible with Lightning-Link®.If your antibody contains BSA, you can now use our BSA removal kit to purify your antibody in a few simple steps. Please note this kit will also enable you to concentrate your antibody.NB: All the AbSelect kits will ONLY work with antibodies. They will not purify other molecules. The only exception is the concentration and clean up kit (861-0010), which will work with other molecules greater than 10kD.
  8. What is the difference between Lightning-Link® and Lightning-Link® Rapid?
    • The benefit of the Rapid kits is that the conjugates can be generated faster because the conjugation and quenching incubation times are shorter. The antibody/protein/peptide considerations are exactly the same, as is the high quality of the final conjugate. DyLight® dyes are only available in the Rapid format.

Additional Lightning-Link Glucose Oxidase Products

Lightning-Link Glucose Oxidase 706-0015

Blogs on Lightning-Link Glucose Oxidase

There are no specific blogs for Lightning-Link Glucose Oxidase, but you can read our latest blog posts.

Contact Information

Product PDFs

Customer Resources

Novus Review - Submit your review and earn rewards points which can be used for merchandise & discounts.
Risk Free Testing - Test on a species/application not listed above to receive a full credit towards a future purchase.

Novus' Quality Guarantee - Novus guarantees that every product we sell will work in the application and species listed on our website and datasheets.

Submit your question on 706-0015 below.
During business hours, we will respond to your email within 24 hours. For any questions submitted on the weekend, a response will be received on Monday.
For immediate assistance during business hours M- F (excluding major holidays), please contact us.
Ask a Scientist - We have a lab full of white coats just waiting for your scientific questions and concerns.